Attribute | Value |
---|---|
Make | Hyster |
Model | S120FT PRS |
Forklift Type | Cushion Tire - Internal Combustion |
Basic Capacity (lbs/kg) | 12000/5443 |
Load Center (in/mm) | 24/610 |
Power | LPG |
Engine | GM 4.3L |
Tire Type | Cushion Drive, Cushion Steer |
Tilt - standard (forward/back) | 5/6 degrees |
Length to Carriage Front (in/mm) | 106.5/2705 |
Width - standard tires (in/mm) | 52.0/1320 |
Width - wide tread tires (in/mm) | 55.9/1420 |
Height to Top of Overhead Guard Standard (in/mm) | 86/2175 |
Height to Top of Overhead Guard Optional (in/mm) | 83/2108 |
Turning radius (in/mm) | 93.5/2375 |
Right Angle Stack Aisle Width (in/mm) | 115.6/2937 |
Weight with 2-StageLFL Mast - no attachment (lbs/kg) | 18686/8476 |
Front Tire Size | 22x12x16 |
Rear Tire Size | 18x8x12.2 |
Wheelbase (in/mm) | 70.5/1790 |
We have high-quality, ready-to-ship used forklifts at affordable prices in our 30,000 sq ft Ohio warehouse.
FERNANDO –
I HAVE A HYSTER THAT ENGINE SHUTOFF IN 30 SECONDS AFTER IT STARTS
Andy Guild –
If the machine is counting down 30 seconds and then turning off you have an issue the ECU is trying to prevent from getting worse. Check for error codes – if you have any you can post them here and get more info. Otherwise look for main issues like overheating, low coolant, low oil, fuel leaks, etc. If you don’t have a code and can’t find the issue on your own it’s best to call the Hyster dealer.
Andy Guild –
Code 522655-1 – Closed Loop Feedback (LPG) Short Term Fuel Trim High. This means you have an intermittent lean run.
Andy Guild –
We replaced the LP fuel filter and the code persists. Also tried to clean out electronic pressure regulator and code is still there. Trying the regulator diaphragm next.
Andy Guild –
code 2000-12 machine won’t start
Andy Guild –
Check 20 amp fuses in fuse box next to battery. If one is blown this will prevent the machine from starting.