Mitsubishi EDR18N2 Forklift, Battery & Charger Specifications

Make: Mitsubishi
Model: EDR18N2
Forklift Type: Reach Truck Forklift
Basic Capacity (lb/kg): 3500/1580
Load Center (in/mm): 24/600
Power: Electric
Tilt (forward/back): 3/4 degrees
Overall Length (in/mm): 78.1/1983
Length to Fork Face (in/mm): 62.3/1582
Height to Top of Overhead Guard (in/mm): 95/2413
Minimum turning radius (in/mm): 70.74/1797
Weight without battery (lb/kg): 740/3350
Wheelbase (in/mm): 61.5/1562
Tire Size - Steer: 13.5x5.5"
Tire Size - Caster: 7.0x4.0"
Tire Size - load wheels: 5.0x3.62"

Mitsubishi EDR18N2 Battery and Charger Info

36 Volts

Box Dimensions: 16.25 x 38.42 x 31.65"
Max Amp Hours: 1120
Minimum Weight: 2000lbs

Looking For Used Mitsubishi Forklifts?

Machine Maxx USA is committed to customer service and quality used forklifts. We put integrity first so that you can be sure you're doing business with the right people - people just like you!

3 thoughts on “Mitsubishi EDR18N2 Forklift, Battery & Charger Specifications”

  1. Andy Guild
    Reply

    Andy Guild

    Use this section to ask questions and leave comments about the Mitsubishi EDR18N2 forklift.

    • Leng Moua
      Reply

      Leng Moua

      Hey, I drive one of these for work but I keep getting code 1120.01 and apparently no one knows what this code means, including the tech who came out here for it. It doesn’t show up in the machines error log eirh

      • Andy Guild
        Reply

        Andy Guild

        I think this is the error you’re getting:

        Drive wheel slip excessive

        Excessive slip / drive has probably been tipped
        The AC-3 Power Control (U8) has detected excessive
        deviation (slip) between the phase current frequency and
        the speed.
        The activation limit is 20 msec.
        More torque is required from / placed on the motor than it
        can provide / accept;
        Field current is reduced excessively;
        Error accompanying sensor bearing control or output
        stage protection;
        Operating system does not allow enough slip for the
        driven motor;
        AC-3 Power Control component is damaged

        – Check motor connection wire (wire breakage);
        – Check motor model, replace if necessary;
        – Check motor and replace if necessary;

Leave a Reply